- Bonding Agents
- Coatings, Primers & Sealers
- Curing & Hardening Compounds
- Epoxies: Low Viscosity
- Epoxies: Epoxy Repair Compounds
- Epoxies: Trowel Grade
- Fiberglass System & Shapes
- Grouts: Cementitious
- Grouts: Epoxy
- Grouts: Polymer
- Grouts: Polyurethane
- Membranes
- Polyurea
- Sealants
- Admixtures
- Bearings
- Miscellaneous
Home > Product Catalog > Epoxy Repair Compounds > FX-738
FX-738 Metal Filled Trowel Grade
MSDS Download
DESCRIPTION:
FX-738 Metal Filled Trowel Grade is a two-component, 100% solids, metal-reinforced polymeric compound which can be used to repair virtually any metal surface that has been damaged, cracked or worn.
ADVANTAGES:
- Excellent adhesion to all metals
- Machineable
- Can be drilled, tapped or sanded
- Chemical-resistance
- Heat resistance up to 400° F
- No shrinkage
WHERE TO USE:
- Worn shafts
- Keyways
- Hydraulic rams
- Stripped threads
- Cracked engine blocks
- Pumps & valves
PHYSICAL PROPERTIES:
Color |
Gray |
Mix Ratio |
3A:1B |
Pot Life |
20 mins. @ 75°F |
Specific Gravity |
1.65 |
Compressive Strength |
15,000 psi |
Flexural Strength |
13,500 psi |
Shear Strength |
2,400 psi |
SURFACE PREPARATION:
All surfaces to be repaired must be clean of dirt, grease and oil. For best results, remove contamination with abrasive blasting and non-flammable cleaner/degreaser, making sure all dust is removed.
MIXING:
Either mix the entire contents of the base and activator or measure three (3) parts of base and one (1) part of activator, by volume, and mix with spatula thoroughly to produce a streak-free material. Scrape mixing board frequently to insure complete mixing.
APPLICATION:
Apply by brush or applicator. Material should be worked into the profile of the surface to achieve maximum adhesion. Material can be heat-cured for one (1) hour at 200° F to achieve ultimate properties.
PACKAGING:
Available in one (1) kg. units.
COVERAGE:
One (1) kg unit equals 38 cubic inches
LIMITATIONS:
Material should be used in 40° to 90°F temperatures and in less than 90% humidity.
SHELF LIFE:
One (1) year in closed containers. Store between 60°F and 85 °F.
CAUTIONS:
"A" Component: Warning! Contains epoxy resin. May cause skin irritation or allergic response. Avoid contact with skin. Avoid breathing vapors when heated. Wear protective gloves, goggles and barrier creams. In case of skin contact, wash thoroughly with soap and water. In case of ingestion, do not induce vomiting.
"B" Component: Warning! Danger! Causes severe burns. Contains alkaline aimes-strong sensitizer. Avoid skin contact. Avoid breathing vapors when heated. Wear protective gloves, goggles and barrier creams. In case of skin contact, wash thoroughly with soap and water. In case of ingestion, induce vomiting. If irritation persists, seek medical attention.
FOR INDUSTRIAL USE ONLY. KEEP AWAY FROM CHILDREN. 1/2005