Home | Site Map

Home > Product Catalog > Grouts: Cementitious > FX-930

FX-930 Rapid Hardening Cement

Download PDF of FX-930

DESCRIPTION:

FX-930 Rapid Hardening Cement is a fast hardening, non-shrink hydraulic cement. It is especially formulated for concrete repairs where rapid strength gain, good durability, no shrinkage and positive bond are essential. When used as a replacement for Portland Cement, and mixed with water and suitable aggregates, it produces a quality concrete, which attains 2,500+ psi compressive strength in two hours. FX-930 contains no added chlorides.

ADVANTAGES:

FX-930 exceeds all requirements of ASTM C-928. It is especially desirable for patching with minimum downtime. For grout—mix FX-930 cement with sand. For concrete—mix FX-930 cement with sand and coarse aggregate. Amounts may vary depending on strength required. Both fine and coarse aggregate shall meet the requirements of ASTM C-33.

APPLICATIONS:

As a Portland Cement replacement, FX-930 is ideal for applications where quick concrete strength is required, including repairs of highways, runways, sidewalks, and floors.

TECHNICAL DATA

GROUT

FX-930

50 lbs.

Sand

100 lbs.

Water

2.3 gals.

 
CONCRETE

FX-930

720 lbs.

Fine Aggregate

1,200 lbs.

CA

1,600 lbs.

Water

33 gals

PHYSICAL PROPERTIES:

TEST METHOD

GROUT

CONCRETE

Hardening Time (ASTM C-266)

Initial Set

20-30 minutes

25-35 minutes

Final Set

35 minutes

35 minutes

 
Compressive Strength

ASTM C-109

ASTMC-695

2 hours after set

3,000 psi

2,500 psi

1 day

4,000 psi

3,200 psi

7 days

5,500 psi

5,000 psi

28 days

7,000 psi

6,000 psi

 
Freeze/Thaw - NY DOT 502-3P

0% Loss

Good

Expansion/Contraction

0%

0%

Theoretical Yield above mix

1.2 cu. ft.

1 cu. yd.

Length Change CRD-C 621

0

0

Wet Density

135#/cu. ft.

145#/cu. ft.

Bond Strength

520 psi @ 5 days

Flexural Strength, psi
   (ASTM C 78)

5 Hours
650

28 Days
1,260

Modulus of Elasticity, psi
   (ASTM C 469)

28 Days
4,220,000

Cement specific gravity, g/cu. cm

2.98

DIRECTIONS FOR CONCRETE:

Remove all unsound concrete keeping edges and corners square. Adjacent concrete should be free of oil, grease, laitance and debris. Apply FX-752 Bonding Agent or dampen area with water where fresh grout or concrete will be placed against existing concrete.

A slump of approximately 4" is recommended for ease of placement and to assure a good bond. The working time for FX-930 Rapid Hardening Cement is approximately 20 minutes at 70°F (longer at lower temperatures, shorter at higher temperatures).

It is important that the placement operation be organized within this time limitation. After Hardening, the concrete will gain strength quickly, and finishing operations may be difficult. In hot weather, the working time may be extended by using cold materials, ice, and/or FX-343 DP Retarder. In cold weather, warm materials may be used to hasten the set and strength development.

For best results, wet cure or apply FX-15 Membrane Curing Compound.

COVERAGE:

Each 50 lb. (23 kg) bag mixed with 100 lb. sand, and water—will yield approximately 1.2 cu. ft. of mortar.

SHELF LIFE:

One (1) year

LIMITATION:

FX-930 Rapid Hardening Cement should not be used in temperatures below 40°F (4°C) or placed at layers of less than 1/2" (12.7 mm) thick. Areas for patching must be clean; precautions should be taken when sandblasting or when compressors are used, that water and oil collection traps are used.

CAUTION:

Contains cementitious materials. Freshly mixed materials may cause skin irritation or skin injury. Avoid contact with skin and wash exposed skin areas promptly with water. If any cement powder or mixture gets into eyes, rinse immediately and repeatedly with water and get prompt medical attention. SEE MSDS.

FOR INDUSTRIAL USE ONLY. KEEP AWAY FROM CHILDREN. 12/2004